7.6.2. PGM output names
Each PGM output has a name that can be customized by the user. Typically, the name species a device
type connected to a determined PGM output, for Example: Lights. The name can be used instead of PGM
output number when controlling the PGM output by SMS text message. By default, the PGM output names
are: C1 – Controll1, C2 – Controll2, C3 – Controll3, C4 – Controll4 etc.
ATTENTION: Space, colon, semi-colon characters, parameter names and/or values, such as PSW,
STATUS, ON, OFF etc. are NOT allowed in PGM output names.
7.6.3. Turning PGM outputs ON and OFF
By default, all PGM outputs are turned OFF and the PGM output state is set to OFF when the system starts-
up.
The PGM output can be turned ON for a determined time period and automatically turned OFF when the
time period expires. As well as it can be turned OFF for a determined time period and automatically turned
ON when the time period expires
When the PGM output is turned ON or OFF, the system will send a conrmation by SMS text message to the
user phone number that the SMS text message was sent from.
NOTE: PGM output can be turned ON for a determined time period only when it is in OFF state
NOTE: PGM output can be turned OFF for a determined time period only when it is in ON state
7.6.4. PGM output type denitions
• Output – Operates as normal PGM output that can be controlled by the user. Normally, this type is
used for any device or relay.
• Siren – Operates as siren output that automatically activates during alarm. Typically, this type is used
for bell/siren connected to EW2,EW2B wireless device.