ADL 2010 / 01 38/57 599 72 63-27
E62
Heating unit power relay faulty.
Heating unit faulty.
Faulty wiring.
Main circuit board faulty.
Forced cooling cycle OFF
E63
Heating unit automatic reset thermostat triggered.
Thermostat faulty (replace heating unit).
Heating unit faulty.
Faulty wiring.
Main circuit board faulty.
Turn the power supply to the heating unit off.
If the problem ceases, the alarm will be
stored and the cycle will continue. If the fault
persists after attempting to repower the
appliance a few times, the alarm E62 is
triggered.
OFF
E64
Heating element thermostat.
Heating element thermostat faulty.
Faulty wiring.
Main circuit board faulty.
E71
NTC1 probe malfunction.
NTC1 probe faulty.
Faulty wiring.
Main circuit board faulty.
Forced cooling cycle OFF
E82
Selector malfunction in OFF position.
Circuit board wiring.
Board faulty
E83
Incorrect selector positions.
Circuit board wiring.
Board faulty.
E93
Appliance configuration error.
Bad EEPROM configuration.
Main circuit board faulty.
Cycle blocked OFF
E94
Drying cycle configuration error.
Bad EEPROM configuration.
Main circuit board faulty.
Cycle blocked OFF
E97
Inconsistency between selector and cycles. Configuration error. Cycle blocked OFF
EH1
Appliance power supply frequency
outside limits.
Problem with the power supply network
(incorrect/disturbed).
Main circuit board faulty.
Cycle blocked. If the power supply becomes
stable again before the time-out, the cycle will
restart.
OFF
EH2
Power supply voltage too high.
Problem with the power supply network
(incorrect/disturbed).
Main circuit board faulty.
Cycle blocked OFF
EH3
Power supply voltage too low.
Problem with the power supply network
(incorrect/disturbed).
Main circuit board faulty.
Cycle blocked. If the power supply becomes
stable again before the time-out, the cycle will
restart.
OFF