ADL 2010 / 01 49/57 599 72 63-27
13.15 NTC probe
1. Remove the probe towards the inside of the
machine.
2. Move the connector fastening clip slightly, and
remove the connector.
13.16 Running capacitor
1. Disconnect the connectors.
2. Move the fastening hook and remove it by
pulling upwards.