11 Alarm Summary Table
Alarm Description Possible fault Machine status/action
Reset
command
E00
No alarm. --- --- ---
E31
Conductivity sensor signal frequency too high. Main circuit board faulty Alarm only active in diagnosis mode. ---
E32
Conductivity sensor signal frequency too low.
Faulty wiring.
Brushes worn/faulty.
Main circuit board faulty.
Cycle blocked OFF
E45
Door closed sensor.
Door lock faulty.
Faulty wiring.
Main circuit board faulty
Cycle blocked OFF
E51
Motor power supply TRIAC short-circuiting.
Motor faulty.
Faulty wiring.
Main circuit board faulty.
Cycle blocked OFF
E52
Motor thermal cutout triggered.
Motor faulty.
Motor thermal cutout has triggered.
Faulty wiring.
Main circuit board faulty
Cuts the power supply to the heating unit and
to the motor. If the problem ceases, the alarm
will be stored and the cycle will continue. If
the fault persists after attempting to repower
the appliance a few times (approximately 35
min.), alarm E51 is triggered.
OFF
E53
Motor TRIAC "sensing" circuit faulty. Main circuit board faulty. Cycle blocked OFF
E54
Motor blocked.
Washing load is too large.
Power supply voltage low.
Motor/drive system blocked.
Cycle in pause after several attempts to re-
power the motor.
Start