ADL 2010 / 01 57/57 599 72 63-27
15 Final testing of door fastening
To check whether door fastening complies with safety regulations after the door has been reversed, proceed
as follows:
prepare a loop (1) (of string, thread, etc.),
position it around the latch, close the door.
Check the door opening safety load as follows:
fasten a dynamometer to the loop (2),
then pull the instrument perpendicular to the surface of
the door. The scale should indicate:
MAX. 51 NEWTON (kg 5.1)
min. 38,2 NEWTON (kg 3.8).
N.B.: This locking system has been designed to allow a child who has accidentally been shut inside
the tumble dryer to open the door simply by pushing it.
The appliance complies with current regulations.