Device filling/emptying
© Elma Schmidbauer GmbH BA_Elmasteam_8_Vers.07.2016
1.2.3
CAREFUL
Escaping steam!
Prevent scalding caused by unforeseen vapour
formation during filling!
• Allow the device to cool down after full pressure
discharge for approx. 5 minutes.
• Do not lean over the filling opening of the pressure
2. Slowly open the pressure vessel screw cap as residual steam
can escape laterally from the pressure vessel screw cap
3. Insert the sieve (Figure 6.2.2) from the scope of delivery into
the collection tray.
WARNING
Possible short circuit in the device from the
ingress of water into the housing!
Electric shock, serious injury!
• Refill with water slowly.
• Avoid overfilling. Observe the operating displays.
• Water must not ingress into the ventilation slots of
the device cover.
• Regularly inspect the seal on the pressure vessel
screw cap.
• Replace the seal on the pressure vessel screw cap
4. Refill with water slowly.
Ensure that you do not overfill the pressure vessel. Observe
the operating display for the filling level (the display level goes
out when the maximum level has been achieved).
The filling level is displayed on the operation display:
• The operating display warning will go out when the
minimum filling level has been achieved.
• The operating display warning will go out when the
maximum filling level has been achieved.
5. The pressure vessel is completely filled when the operating
display for the filling level goes out.
6. Remove the sieve.
7. Wipe away any overflowing water.
8. Close the pressure tank screw cap manually (hand tight).
Allow to device to
cool down after
pressure build-
Filling the pressure
vessel
Observe the
operating displays
Close the pressure vessel
screw cap