Device filling/emptying
BA_Elmasteam_8_Vers.07.2016 © Elma Schmidbauer GmbH
6.2 Manual Filling
INFORMATION
Pressure-free device
• Commence the filling with Point 2 for pressure-free
devices. Observe the gauge display! The device
remains under pressure as long as one segment is
illuminated on the value scale on the gauge.
• Always firstly discharge the pressure with heated
up devices! Observe the gauge display, pressure
values illuminate as green when the pressure
vessel is pressurised! Commence the filling with
INFORMATION
The device is switched off and depressurised.
• Observe the maximum filling capacity (Chapter 3.4
Technical Data).
• Fill the device slowly to prevent overfilling.
The commissioning was executed (Chapter 4).
The device is switched on at the mains supply switch!
The device is ready for use!
1. Let the remaining steam pressure discharge through the
nozzle. Utilise hereby the function steam outlet (Chapter
7.4.1).
1.1. Device version with manual unit:
1.1.1 Hold the manual unit in a sink or in a bucket until no steam
discharges any more.
1.1.2 Hold down the steam button for 2 seconds to discharge any
residual steam vapour pressure. Steam escapes
permanently. To interrupt, press the steam button again.
1.2 Device version with fixed nozzle:
1.2.1 Position the unit with a fixed nozzle over a sink or suitable
bucket until no more steam discharges.
1.2.2 Hold down the foot switch for 2 seconds to discharge any
residual steam vapour pressure. Steam escapes
permanently. To interrupt, press the foot switch again.
Pressure reduction
with operating display
filling level