Device filling/emptying
© Elma Schmidbauer GmbH BA_Elmasteam_8_Vers.07.2016
6 Device filling/emptying
CAREFUL
Escaping steam!
Risk of scalding!
• Cool down the device before opening.
• Open the pressure tank screw cap only in
depressurised units. Observe the gauge display
(Figure 6-D)! The device remains under pressure
as long as one segment is illuminated on the value
scale on the gauge.
• Device with residual pressure. The scale on the
pressure gauge indicator illuminates.
Let the steam escape via steam outlet.
• Ensure that the escaping steam will not endanger
people, fixtures or equipment.
• The residual steam pressure must be discharged
on the handpiece or on the fixed nozzle.
INFORMATION
Operating Displays for Filling Level and Warning
• Level (B) flashes: no pump operation possible
(Chapter 8.7)
• Level (B) illuminates: If necessary, top up the
device (filling level between minimum and
maximum) The indicator (B) goes out as soon as
pressure is built up in the device.
• Level (B) does not illuminate: Device is full (filling
level maximum)
• Level (B) illuminates + Warning (A) flashes +
Warning Tone, during the operation soft or strong.
Top up the device (filling level below minimum.)
The display for filling level goes out when the
device is completely filled.
• The warning (A) goes out as soon as the filling
level minimum is achieved
device coo