MES53xx, MES33xx, MES23xx Ethernet Switch Series 56
Clock is synchronized, stratum 3, reference is 10.10.10.1, unicast
Unicast servers:
Server : 10.10.10.1
Source : Static
Stratum : 3
Status : up
Last Response : 10:37:38.0 UTC Jun 22 2016
Offset : 1040.1794181 mSec
Delay : 0 mSec
Anycast server:
Broadcast:
In the example above, the system time is synchronized with server 10.10.10.1, the last response is
received at 10:37:38; system time mismatch with the server time is equal to 1.04 seconds.
5.8 Configuring time ranges
Commands for configuring the time ranges
console# configure
console(config)# time-rangerange_name, where
range_name – symbolic (1...32) time range identifier
console(config-time-range)#
Table 5.27 – List of time range configuration commands
You can specify the mask value in X.X.X.X format or in /N format, where N is the number of
1's in the binary mask representation.
5.9.1 Ethernet, Port-Channel and Loopback interface parameters
Interface configuration mode commands (interface range)