Service
109
Fig.
93
: Solenoid valve 3/2
Turn the power switch to pos.0.
Unplug the main power plug as well.
Remove the connector (7).
Unscrew the nut (1).
Remove the coil (2) (only with the 2/2 valve).
Unscrew counter-clockwise the hexagon screw on the plunger housing.
Remove the plunger (5) (only with the 2/2 valve)
Caution Do not lose the spring (4)!
With oxygen pressure or compressed air, clean the inside of the plunger housing(3), as
well as the plunger (5) and re-assemble the solenoid valve. With the furnace closed and
renewed oxygen pressure, check to ensure that the solenoid valve is sealed.
2
4
5
7
1
2
3
4
5
7
1
3
66
3-13-1