60
 
    A yellow circle with a number indicates the cable number.
Cabling the VNX5300 with two Control Stations.
1.  Connect the Control Station 0 (CS0) to the customer modem. 
2.  Connect Control Station 0 (CS0) IPMI to CS1.
3.  Connect CS0 MGMT B extension cable to MGMT CS0.
4.  Connect CS1 MGMT B extension cable to MGMT B (optional).
5.  Connect CS 0 MGMT extension cable to local area network (LAN).
6.  Connect CS1 MGMT B extension cable to LAN (optional).
 
If Control Station 1 is not installed you will not need CS1 extension cables or cables 2, 4, and 6.        
1
2
3
4
5
6
#
Serial 
console
MGMT
CS
B
MODEM socket
VGA plug
A
IPMI port
Serial 
console
MGMT
CS
B
MODEM socket
VGA plug
A
IPMI port
PDU B
PDU B
2
Control Station 0
Control Station 1 (optional)
B
MGMT
B
MGMT
B
MGMT
B
MGMT
4
6
3
5
CS
1
2
Blade   Encl 0
MMB   Port 1
3
CS 0           B
Blade   Encl 0
MMB   Port 2
4
CS 1          B
To public local 
area network (LAN)
5
CS0 MGMT
6
CS1 MGMT
Modem
CS0 CS Port
CS1 CS Port
CS1 CS Port
CS0 CS Port
CS 1 
optional
Modem
1
CS
CS 1 
optional
CS 1 
optional
Connect Control Station cables