 Connect SAS DPE and DAE
Cabling between the DPE and optional DAEs uses SAS cables.  The connectors on SAS cables 
have icons indicating each end.
The SAS ports on the DPE are labeled 0 and 1.  Port 0 is connected internally to the SAS 
expander that connects all the internal DPE disks.  Since Port 0 is already connected internally 
to the DPE disks, the first DAE is connected to Port 1 to balance the load on the SAS ports.  The 
second DAE is connected to Port 0; the third DAE is connected to SAS1, and so forth.
To add additional DAEs, see the cabling directions in the VNX5300 Hardware Overview.
    From SP A port 0            to DAE 2 LCC A      
    From SP A port 1            to DAE 1 LCC A
    From SP B port 0            to DAE 2 LCC B      
    From SP B port 1            to DAE 1 LCC B
2
1
4
3
Note: On the 15-drive DAE, because LCC A and LCC B are reversed, the cable connections into LCC 
B and LCC A are also reversed. LCC B will have the tab up, while LCC A will have its tab down. On the 
25-drive DAE the cable connections into LCC B and LCC A are identical. Both LCC B and LCC A will 
have the tab up.
LCC A
SP A  SAS 0