A-13
Reference Data
HAZARDOUS LOCATIONS
CERTIFICATIONS
Factory Mutual (FM) Approvals
E5 Explosion-proof for
Class I, Division 1, Groups B, C, and D;
Dust-Ignition proof for
Class II/III, Division 1, Groups E, F, and G;
factory sealed
I5 Intrinsically safe for use in
Class I, Division 1, Groups A, B, C, and D;
Class II/III, Division 1, Groups E, F, and G;
Temp. code T4 only when connected in accordance with
Rosemount drawings 08800-0106 and 00268-0031;
Non-incendive for
Class I, Division 2, Groups A, B, C, and D;
factory sealed.
Entity Parameters:
U
i
= 30 V
I
i
= 300 mA
P
i
= 1.3 W
C
i
= 0.0
m
F
L
i
= 40
m
H
K5 E5 and I5 combination
U
i
= 30 V
I
i
= 300 mA
P
i
= 1.3 W
C
i
= 0.0
m
F
L
i
= 40
m
H