Table 5-2: Start-up Information on the Rosemount 2410 Display
Item Example
Model number and type (multiple / single tank version) Rosemount 2410
MULTI
Primary communication bus hardware option (TRL2, RS485, Enraf GPU,
HART
®
master, HART slave)
PR HW
RS-485
HART M
HART S
SIL AR
Primary communication bus protocol PRI
MODBUS
Primary Bus communication address ADDR
247
Primary Bus communication settings (Baud rate, stop bits and parity) 9600
1 0
Secondary communication bus hardware option (TRL2, Enraf GPU, HART
wireless, HART master, HART slave, other emulation options)
EN GPU
HART W
HART M
HART S
SIL AR
Secondary communication bus protocol SEC
ENRAF
Secondary Bus communication address 10
Secondary Bus communication settings (Baud rate, stop bits and parity) 1200
1 0
Software version 1.B1
SW
Serial number SN 12
345678
Unit ID (when Modbus is available on Primary or Secondary bus) UNID
23456
Write protection status (ON/OFF) ON
W PROT
Relay option --K2
RELAY
5.4 Error codes
In addition to presenting measurement values, the display can show software and
hardware error messages. In case of an error, the upper row shows “ERROR” and the lower
row toggles between “FAIL” and the error code.