B.5 Europe
B.5.1 E1 ATEX Flame-proof
Certificate
FM10ATEX0012X
Standards
EN 60079-0:2012 + A11:2013, EN 60079 - 1:2014, EN 60079 - 7:2015,
EN 60079 - 11:2012, EN 60529:1992 + A1:2013 + A2:2013
Markings:
TANK HUB
II 2(2) G Ex db eb [ib] IIB T4 Ta = -50°C to 70°C; IP66, IP67
TANK HUB (with Active Modem HART Board)
II 2(2) G Ex db eb [ib] IIB T4 Ta = -50°C to +70°C, IP66 / IP6
II 2(1) G Ex db eb [ia IIC] IIB T4 Ta = -50°C to 70°C; IP66, IP67
TANK HUB (with Passive Modem HART Board)
II 2(2) G Ex db eb [ib] IIB T4 Ta = -50°C to +70°C, IP66 / IP67
II 2 G Ex db eb ib IIB T4 Ta = -50°C to 70°C; IP66, IP67
Ex marking Comm. Bus Ui
V
Ii
mA
Pi
W
Ci
µF
Li
mH
Uo
V
Io
mA
Po
W
Co
µF
Lo
mH
Group
Ex db eb [ib] IIB T4 FISCO - - - - - 15 354 5.32 - - IIB
Ex db eb [ia IIC] IIB
T4
HART/4-20mA
Active
- - - - - 23.1 95.3 0.55 0.14 3.9 IIC
1.0 15 IIB
3.67 33 IIA
Ex db eb ib IIB T4 HART/4-20mA
Passive
30 300 1 0 0 - - - - - IIB
Ex db eb [ib] IIB T4 Fieldbus - - - - - 15 200 3 1.99 143 IIB
Special Conditions for Safe Use (X):
1. The flamepaths of the equipment are not intended to be repaired. Consult the
manufacturer if repair of the flamepath joints is necessary.
Product certifications Reference Manual
December 2019 00809-0100-2410
140 Reference Manual