A Specifications and reference data
A.1 General specifications
A.1.1 Single tank version
Supports one Rosemount 5900S 2-in-1 gauge or up to two Rosemount 5900 standard
gauges
Total Observed Volume (TOV) and API corrected Net Standard Volume (NSV)
calculation with 100-point strapping table
A.1.2
Multiple tank version
For a Rosemount 5300/5408/5900 system configuration:
The software supports 16 field devices and 10 tanks per tank hub
Maximum five type Rosemount 5300 gauges per tank hub
The actual number of tanks/instruments a tank hub supports depends on the
configuration, which types of units are connected and how many:
Hybrid calculations (mass and density) for up to three tanks
Total Observed Volume (TOV) and API corrected Net Standard Volume (NSV)
calculation with 100-point strapping table for one tank
For more information, see Table A-4.
A.1.3
Examples of connected field devices
Radar level gauges (type 5900
(13)
, 5300, and 5408), Rosemount 2240S Multi-input
Temperature Transmitter, Rosemount 644 Temperature Transmitter, Temperature/Water
Level Sensors, Rosemount 3051S Scalable Pressure Transmitter, Rosemount 2230
Graphical Field Display
A.1.4
Start-up time
Less than 30 s
(13) One Rosemount 5900S with a 2-in-1 solution or maximum two standard Rosemount 5900 gauges installed on separate
tanks can be connected to one tank hub.
Reference Manual Specifications and reference data
00809-0100-2410 December 2019
Rosemount 2410 Tank Hub 113