CG Drives & Automation 01-7491-01r0 187
Here the menu shows the run time when the trip occurred.
Fig. 155
Fig. 155 shows the third trip memory menu [810]: Over
temperature trip occurred after 1396 hours and 13 minutes
in Run time.
For Fieldbus integer value of trip message, see message table
for Warning [722].
Trip message [811]-[81Q]
The information from the status menus are copied to the
trip message log when a trip occurs.
810 0rpm
Over temp
1396:13:00
Sby Rem/Rem
NOTE: Bits 0–5 used for trip message value. Bits 6–15
for internal use.
Trip men u
Copied
from
Description
811 711 Process Value
812 712 Speed
813 712 Torque
814 714 Shaft Power
815 715 Electrical Power
816 716 Current
817 717 Output voltage
818 718 Frequency
819 719 DC voltage
81A 71A IGBT Temperature
81B 71B PT100 1, 2, 3
81C 721 VSD Status
81D 723 Digital input status
81E 724 Digital output status
81F 725 Analogue input status 1-2
81G 726 Analogue input status 3-4
81H 727 Analogue output status 1-2
81I 728 I/O status option board 1
81J 729 I/O status option board 2
81K 72A I/O status option board 3
81L 731 Run Time
81M 732 Mains Time
81N 733 Energy
81O 310 Set/View ref
81P 72C VIO Status
81Q 71C PT100 4, 5, 6