©2020 EMS Ltd. All rights reserved. Page 27 of 80 MK067-0001-99 (Issue 1) 04/11/2020 AJM
SYSTEM SETUP
FAULT
NC C NO
FIRE
NC C NO
ACTIVE ACTIVE
FAULT FAULT
INPUT1 INPUT2
A B A B
BAT
ENABLE
TAMPER
RESET
ANTENNA A ANTENNA B
ATTENTION
ELECTROSTATIC
SENSITIVE DEVICE
RS232
EN54-4 UNIVERSAL PSU
SC-60-1000
INPUT: 220-240VAC, 50Hz, 0.3A
OUTPUT: 5.0-8.5VDC, 0.8A MAX
STATUS
FAULT
MAINS / CHARGER FAIL
BATTERY LOW
BATTERY FAIL
START
INPUT
L N
For additional information refer to TSD042
0359-CPR-00267
15
0905
SLIDE TO
REMOVE
EN54-4 UNIVERSAL PSU
SC-60-1000
INPUT: 220-240VAC, 50Hz, 0.3A
OUTPUT: 5.0-8.5VDC, 0.8A MAX
BATTERY LOW
BATTERY FAIL
INPUT
L N
For additional information refer to TSD042
0359-CPR-00267
15
0905
24 VDC dual
output PSU
- +
24V Out
OUTPUT 1
N/C C N/O
Fault
- +
24V Out
N/C C N/O
Fault
OUTPUT 2
Make mains power connections:
230 VAC WZMs only.
Connect both power
inputs.
There are also general
fault inputs (GEN FAULT)
and mains fault (M FAULT)
available.
The fault inputs are NC
and voltage free.
If a fault input (GEN
FAULT or M FAULT) is not
being used, leave the link
as factory fitted.
Make 24 VDC power connections:
24 VDC WZMs only.
Earth wire
Neutral wire
Live wire
220 to
240 VAC
mains
input
*
Additional mains
fault input
DC
POWER
0V V+
M
FAULT
OV V+
GEN
FAULT
A B
1
DC
POWER
0V V+
M
FAULT
OV V+
GEN
FAULT
A B
2
FAULT
NC C NO
FIRE
NC C NO
ACTIVE ACTIVE
FAULT FAULT
INPUT1 INPUT2
A B A B
DC
POWER
0V V+
M
FAULT
A B
GEN
FAULT
A B
1
POWER
0V V+
MAINS
FAULT
A B
GEN
FAULT
A B
2
FAULT
NC C NO
DC
POWER
0V V+
M
FAULT
A B
GEN
FAULT
A B
1
DC
POWER
0V V+
M
FAULT
A B
GEN
FAULT
A B
2
- +
24V Out
OUTPUT 1
NC C NO
Fault
OUTPUT 2
- +
24V Out
NC C NO
Fault
*
*
The 24 VDC SmartCell WZM is designed to be powered from 2x 24 VDC power sources, to meet country
specific requirements.
EOL
(+) (-) (+) (+) (-) (+) (-) (+) (-) (+) (+) (-)
SOUNDER A
L1 L1 L2 EOL ALARM L1 L1 L2
IN OUT RES IN OUT
ZONE
A
B
C
D
EOL
(+) (-) (+) (+) (-) (+) (-) (+) (-) (+) (+) (-)
SOUNDER A
L1 L1 L2 EOL ALARM L1 L1 L2
IN OUT RES IN OUT
ZONE
A
B
C
D