P100 USERS MANUAL JUN2014v03
7
The P100 maintains key sample run parameter data within its internal memory, which is maintained until the memory buffer
is cleared by the user or unit administrator, and/or if the 500 sample run memory buffer capacity is exceeded. Based on
administrative options, the unit will either allow no more runs to be taken with the unit until the run data is reviewed and
cleared, or it will remove the oldest run stored with each new run take. The data maintained in the system includes
set/actual flow rate, set/actual sample volume, sample start/end times, set delay, test and hold period, equipment and serial
numbers, calibration date and due date of the controller/air sampler(s), user defined site description, user ID, and alarms
during sampling. An alphanumeric keypad is provided on the touch screen for entering user defined site
identifiers/descriptions. All sample runs are date and time stamped and are also assigned a unique sample identification string
which is comprised of the units assigned serial number and a non-repeating character string up to 99,999 samples. The run
data cannot be altered within the CPU system of the P100. It may only be output (via USB Stick, or Printer), viewed (via
LCD, or PC), or cleared from the system.
Sample runs on the P100 can be initiated through either the P100 touch screen Run Display screen, the supplied Infrared
Remote (IR Remote), or by remote PC operation (optional). Using either the P100 display, IR Remote, or PC (optional), the
user can START, PAUSE, RESUME, or STOP a sampling session. The IR Remote allows for these functions at a distance
of up to 40-Feet, or approximately 12 meters, with line of site to the P100 IR Receiver window located just above the touch
screen display on the P100. The supplied single IR remote can operate up to 5 P100’s with different IR ID#’s set on the unit
(user selectable IR ID#’s 1 through 5).
There are several options available for the P100. This includes a handheld thermal printer, Remote PC/Ethernet based
operation, horizontal flow inlet, compressed air/gas testing kit, remote exhaust kit, and remote sampling kit. The thermal
printer is battery operated and can utilize both paper or label stock available from EMTEK. There are two options for the
label stock. This includes labels that use black mark detection with backing and a tear of perforation, or liner-less labels (no
backing-self sticking) without tear of perforations. The printer outputs the defined key sample parameter data following
each run (if desired). Additionally, the user can output duplicate labels/data from sample data stored in the memory buffer
based on a requested number of samples. The Remote PC Operations software will allow single or multiple unit control via
Ethernet connection. The horizontal flow inlet allows for testing in areas of horizontal air flow such as horizontal flow
Laminar Air Flow Hoods/Benches. Compressed air/gas testing can be performed at 100 LPM with the addition of the
Compressed air/gas adapter and EMTEK’s Microbial High Pressure Diffuser. The remote exhaust kit allows for attachment
of tubing to exhaust sampled air away from, or outside of the location being sampled (e.g., Isolator, ISO 5 Filling Line, LAF
Hood, etc.). The custom carrying case allows for transport of the standard P100 kit, as well as key optional accessories.