Deltabar S
32 Endress+Hauser
Process connections PMD70
with ceramic process isolating
(continued)
P01-PMD70xxx-06-09-xx-xx-001
Process connection PMD70, version G, PVDF inlay, PN = 10 bar, process temperature T = –10...+60°C (14...+140°F)
H Device height see ä 32, section "Device height H"
Device height H
41.3
54
84
96
PVDF
108
7/16-20 UNF
1/4-18 NPT
H
+
–
+
Version Connection Mounting Material Weight
1
1) Process connection weight, for housing weight see ä 51
G 1/4-18 NPT IEC 61518 7/16-20 UNF PVDF 3.8 kg
Description Device height H
T14 housing, optional display on the side 253 mm
T15 housing without display, flat cover 259 mm
T15 housing with display, high cover 271.5 mm
T17 housing, optional display on the side 269 mm