Deltabar S
68 Endress+Hauser
PMD70 (continued)
50 Calibration; Unit:
1 Nominal range; mbar/bar
2 Nominal range; kPa/MPa
3 Nominal range; mmH
2
O/mH
2
O
4 Nominal range; inH
2
O/ftH
2
O
6 Nominal range; psi
8 Adjusted for Deltatop; see additional specification
B Customised; see additional specification
C Factory certificate 5-point; see additional specification
D DKD certificate; see additional specification
K Platinum; see additional specification
L Platinum and factory certificate 5-point; see additional specification
MPlatinum and DKD certificate; see additional specification
70 Process connection; Material:
B 1/4 – 18 NPT IEC 61518, mounting: 7/16 – 20 UNF, C22.8 (CRN)
D 1/4 – 18 NPT IEC 61518, mounting: 7/16 – 20 UNF, AISI 316L (CRN)
F 1/4 – 18 NPT IEC 61518, mounting: 7/16 – 20 UNF, Alloy C (CRN)
G 1/4 – 18 NPT IEC 61518, mounting: 7/16 – 20 UNF, PVDF
U RC 1/4 mounting: 7/16 – 20 UNF, AISI 316L (CRN)
1 1/4 – 18 NPT, mounting: PN 160: M10, C22.8 (CRN)
2 1/4 – 18 NPT, mounting: PN 160: M10, AISI 316L (CRN)
3 1/4 – 18 NPT, mounting: PN 160: M10, Alloy C (CRN)
80 Seal:
A FKM Viton
BEPDM
DKalrez
EChemraz
1 FKM Viton,
cleaned from oil and greace
2 FKM Viton, cleaned for oxygen service
Note application limits pressure/temp.
100 Additional option 1:
A not selected
E SIL/IEC 61508 Declaration of conformity
B Material test certificate for wetted components, inspection certificate as per
EN 10204 3.1 acc. to specification 52005759
M Overvoltage protection
J Software adjustment, see additional spec.
N HistoROM/M-DAT
S GL/ABS marine certificate
U Mounting bracket, wall/pipe, 304
V Mounting on shut-off valve from above
W Mounting on shut-off valve from below
2 Test report acc. to EN10204 2.2
3 Routine test with certificate, inspection certificate as per EN 10204 3.1
4 Overpressure test with certificate,
inspection certificate as per EN 10204 3.1
110 Additional option 2:
A not selected
E SIL/IEC 61508 Declaration of conformity
B Material test certificate for wetted components, inspection certificate as per
EN10204 3.1 acc. to specification 52005759
G Separate housing, cable length see additional spec. + mounting bracket,
wall/pipe, 316L
(FM /CSA IS: nur für Div.1 Installation)
K Vent valves (2 pieces), Alloy C
M Overvoltage protection
J Software adjustment, see additional spec.
N HistoROM/M-DAT
R Screws 7/16 UNF, length 1 1/2" (4 pieces) for oval flange adapter PZO
S GL/ABS marine certificate
U Mounting bracket for wall/pipe, AISI 304
2 Test report acc. to EN10204 2.2
3 Routine test with certificate, inspection certificate as per EN 10204 3.1
4 Overpressure test with certificate, inspection certificate as per EN 10204 3.1
5 Helium leak test EN 1518 with test certificate,
inspection certificate as per EN 10204 3.1