Technical data iTEMP TMT82
58 Endress+Hauser
TA30H with display window in cover Specification
125 (4.92)
115 (4.53)
28
(1.1)
78 (3.01)
20.5 (0.8)
A0009831
• Flameproof (XP) version, explosion-protected, captive
screw cap, with two cable entries
• Temperature: –50 to +150 °C (–58 to +302 °F) for rubber
seal without cable gland (observe max. permitted
temperature of cable gland!)
• Material: aluminum; polyester powder coated
• Cable entry glands: ½" NPT, M20x1.5
• Color of head: blue, RAL 5012
• Color of cap: gray, RAL 7035
• Weight: approx. 860 g (30.33 oz)
TA30D Specification
107.5 (4.23)
110 (4.3)
28
(1.1)
78 (3.1)
15.5 (0.6)
A0009822
• 2 cable entries
• Temperature: –50 to +150 °C (–58 to +302 °F) without
cable gland
• Material: aluminum, polyester powder coated
Seals: silicone
• Cable entry glands: 1/2" NPT and M20x1.5
• Two head transmitters can be mounted. In the standard
configuration one transmitter is mounted in the terminal
head cover and an additional terminal block is installed
directly on the insert.
• Color of head: blue, RAL 5012
• Color of cap: gray, RAL 7035
• Weight: 390 g (13.75 oz)
Maximum ambient temperatures for cable glands
Type Temperature range
Polyamide cable gland ½" NPT, M20x1.5 (non-Ex) –40 to +100 °C (–40 to 212 °F)
Polyamide cable gland M20x1.5 (for dust ignition-proof area) –20 to +95 °C (–4 to 203 °F)
Brass cable gland ½" NPT, M20x1.5 (for dust ignition-proof area) –20 to +130 °C (–4 to +266 °F)
Weight • Head transmitter: approx. 40 to 50 g (1.4 to 1.8 oz)
• Field housing: see specifications
• DIN rail device: approx. 100 g (3.53 oz)
Materials All the materials used are RoHS-compliant.
• Housing: polycarbonate (PC), corresponds to UL94, V-2 UL recognized
• Terminals:
– Screw terminals: nickel-plated brass and gold-plated contacts
– Spring terminals (head transmitter): tin-plated brass, contact springs 1.4310, 301
(AISI)
• Potting (head transmitter): WEVO PU 403 FP / FL
Field housing: see specifications