Technical data Liquiphant FTL62 HART
56 Endress+Hauser
IP66/IP68 NEMA 4X/6P (1.83 m H
2
O for 24 h)
Types of housing:
Single compartment; aluminum, coated; Ex d/XP
Dual-compartment, L-shape; aluminum, 316L; Ex d/XP
Degree of protection for M12 plug
When housing is closed and connecting cable is plugged in: IP66/67 NEMA Type 4X
When housing is open or connecting cable is not plugged in: IP20, NEMA Type 1
NOTICE
M12 plug: Loss of IP protection class due to incorrect installation!
The degree of protection only applies if the connecting cable used is plugged in and
screwed tight.
The degree of protection only applies if the connecting cable used is specified according
to IP67 NEMA Type 4X.
Ordering information: Select the required option in the order code for "Electrical
connection". Exclusion criteria are taken into account automatically.
15.3.7 Vibration resistance
As per IEC60068-2-64-2008
a(RMS) = 50 m/s
2
, f = 5 to 2 000 Hz, t = 3 axes x 2 h
15.3.8 Shock resistance
In accordance with IEC60068-2-27-2008: 300 m/s² [= 30 g
n
] + 18 ms
g
n
: standard acceleration of gravity
15.3.9 Mechanical load
Support the device in the event of severe dynamic load. Maximum lateral loading capacity
of the pipe extensions and sensors: 75 Nm (55 lbf ft).
A
  For more details, see the "Supporting the device" section.
15.3.10 Pollution degree
Pollution level 2
15.3.11 Electromagnetic compatibility (EMC)
Electromagnetic compatibility as per EN 61326 series and NAMUR recommendation
EMC (NE21)
With regard to the safety function (SIL), the requirements of EN 61326-3-x are satisfied
Maximum deviation under disturbance: < 0.5% of span
 For more details, refer to the EU Declaration of Conformity.
15.4 Process
15.4.1 Process temperature range
ECTFE: –50 to +120 °C (–58 to +248 °F)
PFA: –50 to +150 °C (–58 to +302 °F)
Enamel:–50 to +150 °C (–58 to +302 °F)
Pay attention to the pressure and temperature dependency.  Additional details in the
"Process pressure range" section.