The flowmeter for highest medium temperatures with an ultra-compact
transmitter
Application
The electromagnetic measuring principle is unaffected by
pressure, temperature and flow profile
Dedicated for chemical and process applications with
corrosive liquids and high medium temperatures
Device properties
Nominal diameter: max. DN 600 (24")
All common Ex approvals
Liner made of PTFE or PFA
Robust, ultra-compact transmitter housing
Pre-configured plug connector
Your benefits
Versatile applications – wide variety of wetted materials
Energy-saving flow measurement – no pressure loss due to
cross-section constriction
Maintenance-free – no moving parts
Space-saving transmitter – full functionality on smallest
footprint
Time-saving local operation without additional software and
hardware – integrated web server
Integrated verification – Heartbeat Technology™
Products Solutions Services
Technical Information
Proline Promag P 100
Electromagnetic flowmeter
TI01102D/06/EN/02.13
71233384

Table of Contents

Other manuals for Endress+Hauser Proline Promag P 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Proline Promag P 100 and is the answer not in the manual?

Endress+Hauser Proline Promag P 100 Specifications

General IconGeneral
Measurement PrincipleElectromagnetic
Housing MaterialAluminum, Stainless steel
Pressure RangeUp to 40 bar (depending on nominal diameter)
Output Signal4-20 mA
Digital communicationHART
LiningPTFE, PFA
Electrode materialStainless Steel
Degree of protectionIP66/67
Accuracy±0.5% of reading ± 1 mm/s (±0.04 in/s)
Temperature Range-20 to +60 °C (ambient), -40 to +130 °C (process)