Proline Promag P 100
Endress+Hauser 11
Galvanic isolation
The following connections are galvanically isolated from each other:
Outputs
Power supply
Protocol-specific data HART
Manufacturer ID 0x11
Device type ID 0x3A
HART protocol revision 6.0
Device description files
(DTM, DD)
Information and files under:
www.endress.com
HART load Min. 250 Ω
Dynamic variables The measured variables can be freely assigned to the dynamic variables.
Measured variables for PV (primary dynamic variable)
Off
Volume flow
Mass flow
Corrected volume flow
Flow velocity
Corrected conductivity
Temperature
Electronics temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary
dynamic variable)
Volume flow
Mass flow
Corrected volume flow
Flow velocity
Corrected conductivity
Temperature
Electronics temperature
Totalizer 1
Totalizer 2
Totalizer 3
PROFIBUS DP
Manufacturer ID 0x11
Ident number 0x1561
Profile version 3.02
Device description files (GSD,
DTM, DD)
Information and files under:
www.endress.com
www.profibus.org