Proline Promag P 100
Endress+Hauser 35
If operating outdoors:
Install the measuring device in a shady location.
Avoid direct sunlight, particularly in warm climatic regions.
Avoid direct exposure to weather conditions.
Temperature tables
The following interdependencies between the permitted ambient and fluid temperatures apply when
operating the device in hazardous areas:
Ex nA,
C
CSA
US
NI
SI units
T
a
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
30 50 95 130 150 150 150
50 95 130 150 150 150
60 95 110 110 110 110
US units
T
a
[°F]
T6
[185 °F]
T5
[212 °F]
T4
[275 °F]
T3
[392 °F]
T2
[572 °F]
T1
[842 °F]
86 122 203 266 302 302 302
122 203 266 302 302 302
140 203 230 230 230 230
Storage temperature
The storage temperature corresponds to the operating temperature range of the measuring
transmitter and the appropriate measuring sensors.
Protect the measuring device against direct sunlight during storage in order to avoid unacceptably
high surface temperatures.
Select a storage location where moisture cannot collect in the measuring device as fungus or
bacteria infestation can damage the liner.
If protection caps or protective covers are mounted these should never be removed before
installing the measuring device.
Degree of protection
Transmitter and sensor
As standard: IP66/67, type 4X enclosure
With the order code for "Sensor options", option CM: IP69K can also be ordered
When housing is open: IP20, type 1 enclosure
Shock resistance
As per IEC/EN 60068-2-31
Vibration resistance
Acceleration up to 2 g following IEC 60068-2-6
Mechanical load
Protect the transmitter housing against mechanical effects, such as shock or impact.
Never use the transmitter housing as a ladder or climbing aid.
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Complies with emission limits for industry as per EN 55011 (Class A)
Device version with PROFIBUS DP: Complies with emission limits for industry as per EN 50170
Volume 2, IEC 61784
The following applies for PROFIBUS DP: If baud rates > 1.5 MBaud an EMC cable entry must be
used and the cable shield must continue as far as the terminal wherever possible.
Details are provided in the Declaration of Conformity.