Proline Promag P 100
48 Endress+Hauser
Fitted electrodes
Measuring electrodes, reference electrodes and electrodes for empty pipe detection:
Standard: 1.4435 (316L), Alloy C22, platinum, tantalum
Optional: only measuring electrodes made from platinum or tantalum
Process connections
EN 1092-1 (DIN 2501): DN ≤ 300 (12") form A, DN ≥ 350 (14") flat face; dimensions as per
DIN 2501, DN 65 PN 16 and DN 600 (24") PN 16 only as per EN 1092-1
ASME B16.5
JIS B2220
AS 2129 Table E
AS 4087 PN 16
For information on the materials of the process connections (→  47)
Surface roughness
Electrodes with 1.4435 (304L), Alloy C22, platinum, tantalum:
≤ 0.3 to 0.5 µm (11.8 to 19.7 in)
(All data relate to parts in contact with fluid)
Liner with PFA:
≤ 0.4 µm (15.7 µin)
(All data relate to parts in contact with fluid)
Operability
Operating concept
Operator-oriented menu structure for user-specific tasks
Commissioning
Operation
Diagnostics
Expert level
Rapid and safe commissioning
Individual menus for applications
Menu guidance with brief explanations of the individual parameter functions
Reliable operation
Operation in the following languages:
Via "FieldCare" operating tool:
English, German, French, Spanish, Italian, Dutch, Chinese, Japanese
Via Web browser:
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
Uniform operating philosophy applied to operating tools and Web browser
If replacing the electronic module, transfer the device configuration via the plug-in memory
(HistoROM DAT) which contains the process and measuring device data and the event logbook. No
need to reconfigure.
For devices with Modbus RS485, the data recovery function is implemented without the plug-in
memory (HistoROM DAT).
Efficient diagnostics increase measurement availability
Troubleshooting measures can be called up via the operating tools and Web browser
Diverse simulation options
Status indicated by several light emitting diodes (LEDs) on the electronic module in the housing
compartment
Remote operation Via HART protocol
This communication interface is present in the following device version:
Order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output