EasyManua.ls Logo

Endress+Hauser Proline Promag P 100 - Workplace and Operational Safety

Endress+Hauser Proline Promag P 100
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promag P 100
6 Endress+Hauser
Safety IT security
We only provide a warranty if the device is installed and used as described in the Operating
Instructions. The device is equipped with security mechanisms to protect it against any inadvertent
changes to the device settings.
IT security measures in line with operators' security standards and designed to provide additional
protection for the device and device data transfer must be implemented by the operators themselves.
Endress+Hauser can be contacted to provide support in performing this task.
Input
Measured variable Direct measured variables
Volume flow (proportional to induced voltage)
Electrical conductivity
Calculated measured variables
Mass flow
Corrected volume flow
Corrected electrical conductivity
Measuring range
Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy
Electrical conductivity: 5 to 10 000 µS/cm/cm
Flow characteristic values in SI units
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.3/10 m/s)
Current output full scale
value
1)
(v ~ 2.5 m/s)
Pulse value
1)
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[mm] [in] [dm
3
/min] [dm
3
/min] [dm
3
] [dm
3
/min]
15 ½ 4 to 100 25 0.2 0.5
25 1 9 to 300 75 0.5 1
32 15 to 500 125 1 2
40 1 ½ 25 to 700 200 1.5 3
50 2 35 to 1 100 300 2.5 5
65 60 to 2 000 500 5 8
80 3 90 to 3 000 750 5 12
100 4 145 to 4 700 1200 10 20
125 220 to 7 500 1850 15 30
150 6 20 to 600 m
3
/h 150 m
3
/h 0.03 m
3
2.5 m
3
/h
200 8 35 to 1 100 m
3
/h 300 m
3
/h 0.05 m
3
5 m
3
/h
250 10 55 to 1 700 m
3
/h 500 m
3
/h 0.05 m
3
7.5 m
3
/h
300 12 80 to 2 400 m
3
/h 750 m
3
/h 0.1 m
3
10 m
3
/h
350 14 110 to 3 300 m
3
/h 1 000 m
3
/h 0.1 m
3
15 m
3
/h
400 16 140 to 4 200 m
3
/h 1 200 m
3
/h 0.15 m
3
20 m
3
/h
450 18 180 to 5 400 m
3
/h 1 500 m
3
/h 0.25 m
3
25 m
3
/h

Table of Contents