Proline Promag P 100
36 Endress+Hauser
Process
Medium temperature range
• –20 to +150 °C (–4 to +302 °F) for PFA, DN 25 to 200 (1 to 8")
• –20 to +180 °C (–4 to +356 °F) for PFA high-temperature, DN 25 to 200 (1 to 8")
• –40 to +130 °C (–40 to +266 °F) for PTFE, DN 15 to 600 (½ to 24")
PFA
PTFE
0
0
0
0
-20-40
-40
20
20
40
100
60
140
[°F] [°C]
40 60 80 100
100
120 140 160
200 300
180
360
-20
-40
-40
T
A
T
F
[°F]
[°C]
1
2 3
A0019742
T
A
Ambient temperature
T
F
Medium temperature
1 Gray area: the ambient temperature range of –10 to –40 °C (–14 to –40 °F) applies to stainless flanges
only
2 Hatched area: harsh environment and IP68 only up to +130 °C (+266 °F)
3 Dark-gray area: high-temperature version with insulation
Conductivity
≥ 5 μS/cm for liquids in general
Pressure-temperature
ratings
The following material load diagrams refer to the entire device and not just the process connection.