Proline Promass F 500 Modbus RS485 Technical data
Endress+Hauser 199
DN [mm] Weight [kg]
100 94
150 152
250 398
Weight in US units
DN [in] Weight [lbs]
3/8 20
½ 22
1 26
37
2 62
3 117
4 207
6 335
10 878
Materials Transmitter housing
Proline 500 – digital transmitter housing
Order code for "Transmitter housing":
Option A "Aluminum coated": aluminum, AlSi10Mg, coated
Option D "Polycarbonate": polycarbonate
Proline 500 transmitter housing
Order code for "Transmitter housing":
Option A "Aluminum coated": aluminum, AlSi10Mg, coated
Option L "Cast, stainless": cast, stainless steel, 1.4409 (CF3M) similar to 316L
Window material
Order code for "Transmitter housing":
Option A "Aluminum, coated": glass
Option D "Polycarbonate": plastic
Option L "Cast, stainless": glass
Sensor connection housing
Order code for "Sensor connection housing":
Option A "Aluminum coated": aluminum, AlSi10Mg, coated
Option B "Stainless":
Stainless steel 1.4301 (304)
Optional: Order code for "Sensor feature", option CC "Hygienic version, for maximum
corrosion resistance": stainless steel, 1.4404 (316L)
Option C "Ultra-compact, stainless":
Stainless steel 1.4301 (304)
Optional: Order code for "Sensor feature", option CC "Hygienic version, for maximum
corrosion resistance": stainless steel, 1.4404 (316L)
Option L "Cast, stainless": 1.4409 (CF3M) similar to 316L

Table of Contents