Proline Prosonic Flow 93T Portable Description of Device Functions
Endress+Hauser 83
Function group MULTIPLEX
Functional description
USER INTERFACE INFORMATION LINE MULTIPLEX
ASSIGN
(2620)
Use this function to define a second reading to be displayed in the main line alternately
(every 10 seconds) with the reading defined in the function ASSIGN (2600).
Options
OFF
VOLUME FLOW (CH1)
VOLUME FLOW IN % (CH1)
SOUND VELOCITY (CH1)
SIGNAL STRENGTH (CH1)
FLOW VELOCITY (CH1)
VOLUME FLOW BARGRAPH IN % (CH1)
SIGNAL BARGRAPH IN % (CH1)
ACTUAL CURRENT 1
TOTALIZER (1 to 3)
OPERATING/SYSTEM CONDITIONS
FLOW DIRECTION
ACCUMULATOR CHARGE
ACTUAL CURRENT INPUT
VOLUME FLOW DEVICE 2
Factory setting
OFF
!
Note!
Multiplex mode is suspended as soon as a fault / notice message is generated. The
message in question appears on the display.
Fault message (identified by a lightning icon):
If ON was selected in the function ACKNOWLEDGE FAULTS (8004), multiplex
mode is resumed as soon as the fault has been acknowledged and is no longer
active.
If OFF was selected in the function ACKNOWLEDGE FAULTS (8004), multiplex
mode is resumed as soon as the fault is no longer active.
Notice message (identified by an exclamation mark):
Multiplex mode is resumed as soon as the notice message is no longer active.
If a channel is not visible, it does not appear in the options. Channels can be displayed
or hidden by means of the function MEASUREMENT (6880).
100% VALUE
(2621)
!
Note!
This function is not available unless VOLUME FLOW IN % was selected in the ASSIGN
function (2620).
VOLUME FLOW IN % (CH1)
VOLUME FLOW BARGRAPH IN % (CH1)
SIGNAL BARGRAPH IN % (CH1)
Use this function to define the flow value to be shown on the display as the 100%
value.
User input
5-digit floating-point number
Factory setting
Depends on nominal diameter and country, [value] / [dm
3
to m
3
or US-gal to US-Mgal]
Corresponds to the factory setting for the full scale value ( ä 118).