7.5 Heat Pump: Two-Stage with No Auxiliary Stage
7.5.1 Equipment Wiring
7.5.2 Thermostat Equipment Settings
Setting
Value
EQUIPMENT TYPE
Heat Pump
# OF COOL STAGES
2
# OF HEAT STAGES
2
REV. VALVE
Select whether the reversing valve is on in cool or on in heat. The default is On in
Cool.