EasyManua.ls Logo

Energate FZ100C - 8 Special Configurations; No Common Wire at Thermostat

Energate FZ100C
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE DISCLOSED OR CONVEYED TO,
USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC. PRINTED COPIES WILL BE CONSIDERED UNCONTROLLED.
AW000873-G 35
8 Special Configurations
8.1 No Common Wire at Thermostat
Energate thermostats require a common wire.
If a common wire is not available on the thermostat backplate, do one of the following:
If the HVAC system is a dual-transformer system (two transformers), install an Energate Auxiliary Switch AS20.
See 8.1.1 Installing the Auxiliary Switch (AS20).
OR
If a spare wire is available, run it from the equipment to the thermostat backplate. See 8.1.2 Running a
Common (Ground) Wire.

Table of Contents