EasyManua.ls Logo

Envipco FLEX Series - RVM Communications

Envipco FLEX Series
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
-
21
RV
M
Communications
TABLE 4-3. MC1 Thresholds
Item Description
ANALOG_INPUT_1 Not used.
COMPACTOR1_BLOCKED Longest allowed time w/o state change from decoder wheel
COMPACTOR1_PADDLE paddle-sync time (not used yet; 20130222)
COMPACTOR1_TIMEOUT compactor auto switch off duration
COMPACTOR1_STARTTIME suppress blocked detection on start
COMPACTOR2_BLOCKED longest allowed time w/o state change from decoder wheel
COMPACTOR2_PADDLE paddle-sync time (not used yet; 20130222)
COMPACTOR2_TIMEOUT compactor auto switch off duration
COMPACTOR2_STARTTIME suppress blocked detection on start
COMPACTOR1_TO_FAST shortest allowed time w/o state change from decoder wheel
COMPACTOR2_TO_FAST shortest allowed time w/o state change from decoder wheel
4.6.
RVM Communications
This section describes how the RVMs communicate with each other and with the servers at Envipco
to do the following:
Receive new bar code tables
Receive new RVM software and firmware
Report machine status to Envipco
Send error message logs to Envipco
Send QFiles to Envipco

Table of Contents