EPS NEXUS Manual V1.5.2 EN WWW.EPSBV.EU 39
Voorbeeld 2
Notes:
• It is good to note that filter schedule 2 is set, but is never addressed. In fact, filter schedule 1 has more priority than filter schedule
2. Priority runs from top to bottom (or from 1 to 3).
• Filter schedule 3 only comes up for two hours. Starting at 08:00, filter schedule 1 is set. Filter schedule 1 has a higher priority than
filter schedule 3. Priority runs from top to bottom.
5.7.4 Pump continuously on
If the filter pump is to be on 24/7, this function can be enabled. The filter pump will thus remain on 24/7 at the selected speed.
- Filter schedules can still be set. Filter schedules that have a higher speed set than the "continuous on" feature will cause the pump to run
harder.
5.7.5 Water too hot function
Sometimes a pool can become too warm due to external conditions. If the equipment cannot withstand this, it is advisable to enable the
"water too hot" function. This function causes the filter pump to turn on automatically when the water exceeds 32°C.
By circulating the water, the water cools down faster than if the water remains static. It is recommended to open the cover and further cool
if necessary by adding tap water.
Turning on ‘water too hot’ function
Go to general settings and scroll down. Then go to configuration and type in pin:123.
Scroll down and enable "water temp. protection" and exit the menu.
CAUTION: Never change other parameters in this menu. The configuration screen is for authorized technicians only.