EPS NEXUS Manual V1.5.2 EN WWW.EPSBV.EU 32
5.4 Chlorine settings (#13)
• Desired Rx value.
Here you can set how much chlorine is desirable. The measurement is always relative and thus must be adjusted per pool.
o Chlorine: 775 mV
o Electrolysis and hydrolysis 650 mV
• Dosing time Rx
This parameter allows setting the dosing time of the Rx pump. This determines the size of a dose.
o Chlorine: 60s
o Electrolysis and hydrolysis 0s
• Pause time Rx
This is the time the system will wait after a dose before starting a new dose. The purpose is to give the dosed substances time to mix well
with the swimming water and thus influence the measurement. In this way, the system actually doses only when needed.
o Chlorine: 5m
o Electrolysis and hydrolysis 1m
• Overdose alarm
With this parameter the maximum allowed volume to be dosed per 4 hours is entered. 0.00l/4h = dosing alarm OFF. This error message can
only be reset by restarting the system.
• Threshold water temperature
When a water temperature sensor is connected, the system can stop dosing if it falls below the set value. This is because cold water does
not require water treatment. This setting is connected to that of pH, so changing this setting causes the same thing to happen to the pH
settings.