EPS NEXUS Manual V1.5.2 EN WWW.EPSBV.EU 41
Heating
• This means that the speed and/or on/off times of the filter pump are influenced by the heating of the pool. For example, with the
heating on, the minimum speed of the pump may be higher than that of the filter control. The heater then increases the filter pump
speed and the indication changes to "heating."
• When the interval active of the heater means that the heater must be on for at least x number of minutes, this allows the heater to
keep the pump on until the set time has elapsed. Also then change the indication to "heating".
• If the function "heating priority" is on and the filter times have elapsed, the heating can keep the filter pump switched on. Even
then the indication changes to "heating"
Heating cool down
• When the pump is turned off by a user using the filter schedules or the filter schedules have expired it may be necessary to cool
down the heating. When this setting is greater than 0, the heater will turn off and the filter pump will continue to run for the set
time to cool the heater. After the time has elapsed, the filter pump will turn off.