Setup & Operation 14. Option Slots
RC700 / RC700-A Rev.23 107
EUROMAP connecter
(CN4) Pin No.
Signal Name Note
A5
Not fixed by EUROMAP, manufacturer
dependent
I/O Input (*1)
Reserved for future use by EUROMAP
A9 Supply from IMM
(*1)
Enable movement of core pullers 1 to position 1
Enable movement of core pullers 1 to position 2
Enable movement of core pullers 2 to position 1
Enable movement of core pullers 2 to position 2
C5
Not fixed by EUROMAP, manufacturer
dependent
I/O Input (*1)
Reserved for future use by EUROMAP
Reserved for future use by EUROMAP
C8
Not fixed by EUROMAP, manufacturer
dependent
I/O Input (*1)
*1: DO NOT input a voltage which exceeds 24V. Board may get damage and burnout.