Maintenance  9. Troubleshooting 
 
RC700 / RC700-A Rev.23  283 
7600 
GUI Builder. 
Cannot execute a GUI Builder 
statement from the command 
-     
7602 
GUI Builder. 
GSet parameter is too long. 
Correct the parameter to the proper 
length. 
   
7603 
GUI Builder. 
Too many parameters for GGet. 
Check the number of parameters.     
7604 
GUI Builder. 
Not enough data for GGet statement 
Specify the variable.     
7610 
GUI Builder. 
The event task cannot be executed. 
System in pause state and 
The system can be operated by 
changing EventTaskType to 
“NoPause” 
   
7611 
The event task cannot be executed. 
Safeguard is open and 
The system can be operated by 
changing EventTaskType to 
“NoEmgAbort” 
   
7612 
The event task cannot be executed. 
Estop is active and EventTaskType is 
The system can be operated by 
changing EventTaskType to 
“NoEmgAbort” 
   
7613 
The event task cannot be executed. 
System in error state and 
EventTaskType is not NoEmgAbort. 
The system can be operated by 
changing EventTaskType to 
“NoEmgAbort” 
   
7650 
GUI Builder. 
Specify the valid property.     
7651 
GUI Builder. 
Invalid form. 
Specify the valid form.     
7652 
GUI Builder. 
Invalid control. 
Specify the valid control.     
7653 
GUI Builder. 
The specified form is already open. 
Modify the program to avoid double 
launch. 
   
7654 
GUI Builder. 
Event function does not exist. 
Check the function name set for the 
event. 
   
7655 
GUI Builder. 
Item does not exist. 
Specify the valid item.     
7656 
GUI Builder. 
Invalid property value. 
Check the property value and 
specify the valid value. 
   
7700 
Security. 
Contact the administrator to register 
   
7701 
Security. 
Invalid password. 
Check the password.     
7702 
Security. 
Contact the administrator to set 
   
7703 
Security. 
Option not active. 
Register the options.     
7710 
Source and destination cannot be the 
Specify another destination.     
7711 
Point file name is used by another 
robot. 
Check the point file name.