Maintenance 9. Troubleshooting
286 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
7810
MPL failure.
Failed to open the MPL file.
Reinstall the firmware.
7811
MPL failure.
Failed to read the MPL file.
Update the firmware.
7812
MPL failure.
Failed to write the MPL file.
1. Reboot the controller.
2. Reinstall the firmware.
7815
IFS failure.
Failed to open the IFS file.
Restore the controller configuration.
7816
IFS failure.
Failed to read the IFS file.
Restore the controller configuration.
7817
IFS failure.
Failed to write the IFS file.
Restore the controller configuration.
7822
MTR failure.
Failed to read the MTR file.
1. Reboot the controller.
2. Reinstall the MT.
7824
MTR failure.
Failed to save the MTR file.
Reboot the controller.
7825
PRM failure.
Failed to create the PRM file.
Restore the controller configuration.
7827
PRM failure.
Failed to read the PRM file.
Restore the controller configuration.
7829
PRM failure.
Failed to save the PRM file.
Restore the controller configuration.
7830
File failure.
Cannot access the file.
1. Reboot the controller.
2. Reinstall the firmware.
The motor type is invalid.
Check the motor amplifier.
7840
MCD failure.
Reboot the controller.
7845
FGI failure. Failed to open the FGI
file.
Reboot the controller.
Reinstall the firmware.
- -
7847
MDL failure. Failed to open the MDL
file.
Reboot the controller.
Reinstall the firmware.
- -
7848
MDL failure. Failed to read the MDL
Reboot the controller.
Reinstall the latest firmware version.
- -
Fieldbus invalid parameter.
7902 Fieldbus line defect.
Check the connection of the
communication cable for the
fieldbus.
Check whether the communication
cable for the fieldbus is powered.
(if the fieldbus requires power
supply)
Check the connection of the fieldbus
7903 Fieldbus device not configured.
Check that the fieldbus master
board is installed.
Reboot the computer where the
fieldbus master board is installed.
Replace the fieldbus master board.
7904 Fieldbus invalid board.
Check that the fieldbus master
board is installed.
Reboot the computer where the
fieldbus master board is installed.
Replace the fieldbus master board.
Fieldbus connection denied.