3. Operation
252 RC700 / RC90 Option Fieldbus I/O Rev.14
Default Remote Control Output Setting for Fieldbus Master I/O
Default remote control output settings for fieldbus master I/O are as follows:
Output Signal
Robot System Output Bit No
Ready
6144
Running
6145
Paused
6146
Error
6147
EStopOn
6148
SafeguardOn
6149
SError
6150
Warning
6151
MotorsOn
6152
AtHome
6153
PowerHigh
Not used
MCalReqd
Not used
RecoverReqd
Not used
RecoverInCycle
Not used
WaitingRC
Not used
CmdRunning
6173
CmdError
6174
CurrProg1
6154
CurrProg2
6155
CurrProg4
6156
CurrProg8
Not used
CurrProg16
Not used
CurrProg32
Not used
AutoMode
6157
TeachMode
6158
TestMode
Not used
EnableOn
Not used
ErrorCode1
6159
ErrorCode2
6160
ErrorCode4
6161
ErrorCode8
6162
ErrorCode16
6163
ErrorCode32
6164
ErrorCode64
6165
ErrorCode128
6166
ErrorCode256
6167
ErrorCode512
6168
ErrorCode1024
6169
ErrorCode2048
6170
ErrorCode4096
6171
ErrorCode8192
6172
InsideBox1
Not used
InsideBox2
Not used

Table of Contents

Other manuals for Epson RC90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC90 and is the answer not in the manual?

Epson RC90 Specifications

General IconGeneral
BrandEpson
ModelRC90
CategoryController
LanguageEnglish

Related product manuals