4. Troubleshooting (DeviceNet)
RC700 / RC90 Option Fieldbus I/O Rev.14 289
Status Code
Descriptions
General
Protocol
45
Non-resident dialogue software.
Additional information:
Initialize the applicomIO® interface before use by
running the PcInitIO
47
Targeted applicomIO® card invalid or incorrectly
initialized by the function IO_Init
53
Synchronization problem on the line.
Additional information:
The DeviceNet master is off line” (power supply
not detected or the CAN component of the
applicomIO® is Bus Off)
Check the network wiring and Baud Rate.
55
Response time-out exceeded.
Additional information:
The device accepted the connection but did not
respond the request.
Check the device status.
65
Connection denied.
Additional information:
Connection to the DeviceNet master is in progress
or refused by the device.
70
Connection finished.
Additional information:
Duplication of MAC ID detected on the DeviceNet
network.
Modify the MAC ID of the DeviceNet master.
79
Profile incompatible.
Additional information:
The device does not match the configuration.
Check the device identity and the connection sizes.
63
Indicates that a communication error has been
encountered on serial Port.
66
Not enough applicomIO® interface memory.
93
Driver cannot be accessed.
99
Indicates that applicomIO® solution is already
running.
255
Indicates that the local input buffer was not updated
beforehand by the function IO_RefreshInput.

Table of Contents

Other manuals for Epson RC90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC90 and is the answer not in the manual?

Epson RC90 Specifications

General IconGeneral
BrandEpson
ModelRC90
CategoryController
LanguageEnglish

Related product manuals