SC-F9200 Series Revision C
ADJUSTMENT Overview 261
SE Group Confidential (Related Staff Only)
CR related
parts/units
CR Timing Belt
Replacement 1 Replacement ---
√ √ p. 159
After
replacement
2 Turn the power on in normal mode. ---
√√
3 CR Belt Tension Check
√
Tensimeter U-507
√√
p. 297
4 APG function check
√√√
p. 301
5 CR Scale Check
√√√
p. 304
6 CR Active Damper Adjustment (Automatic)
√√√
p. 305
7 CR Motor Measurement & Automatic Adjustment
√√√
p. 356
8 Manual Uni-d adjustment
√
PGPP
√√
p. 325
9 Manual Bi-d adjustment
√
PGPP
√√
p. 327
CR Unit (CR Assy)
Replacement 1 Replacement ---
√ √
p. 200
After
replacement
2 Turn the power on in normal mode. ---
√√
3 CR Belt Tension Check
√
Tensimeter U-507
√√
p. 297
4 APG function check
√√√
p. 301
5 CR Scale Check
√√√
p. 304
6 CR Active Damper Adjustment (Automatic)
√√√
p. 305
7 CR Motor Measurement & Automatic Adjustment
√√√
p. 356
8 Head inclination manual adjustment (CR direction)
√
PGPP
√√
p. 314
9 Head slant auto adjustment (PF direction)
√
PGPP
√√
p. 319
10 PG Adjustment --- Thickness gauge
√√
p. 306
11 Manual Uni-d adjustment
√
PGPP
√√
p. 325
12 Manual Bi-d adjustment
√
PGPP
√√
p. 327
APG Motor Assy
Replacement 1 Replacement ---
√ √
p. 167
After
replacement
2 Turn the power on in Serviceman mode. ---
√√
3 Reset the motor counter.
√√
--- p. 293
4 APG function check
√√√
p. 301
PW Sensor
Replacement 1 Replacement ---
√ √
p. 204
After
replacement
2 Turn the power on in Serviceman mode. ---
√√
3 Reset the sensor counter.
√√
--- p. 293
Table 4-1. Adjustment items and the order by repaired part
Class
Replaced or Repaired
(Reattached) Part/Unit
Required Operations
Service
Program
Jig Media Replaced Reattached Page