Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908 Revision I
ADJUSTMENT Tests 430
Confidential
5.9.5 Inspection of the SpectroProofer
This inspection checks each part and function of the SpectroProofer operates normally.
INSPECTION CONTEXT
Note : The program for this inspection is the English version only. The above table uses the
names displayed on the program.
PROCEDURE TO START THE INSPECTION PROGRAM
1. Start the Service Program.
2. Select ADJUSTMENTS (Individual).
3. Select Checking SpectroProofer.
4. Click “RUN” to start the program. (The 24 or 44 inches version of the program is
applied automatically according to the model selection of the main menu.)
Figure 5-88. Inspection Program Start Screen
C H E C K
P O I N T
Each inspection item can be executed separately; however, it is
recommended to execute them all in the order given in the table
below.
Table 5-4. Check Items
Category Order Item Content Ref.
MOUNTER
ONLY TESTS
1
Sensors check
Check if Mount Sensor and
Thermistor are operating normally.
p. 431
2
Fan check
Check if Cooling Fan is operating
normally.
p. 433
3
CR move
Check if Carriage is operating
normally.
p. 434
MOUNTER +
ILS TESTS
4
Calibration check
Check if calibration was successful
at the start-up.
p. 436
5
Paper holder
check
Check if Paper Pressing Plate is
operating normally.
p. 437
6
Tile position
check
Check if the white calibration tile
is installed in the correct
attachment location, or is
contaminated.
p. 439
7
Colorimetry CR
Inspection
Check if the Color Measurement
Device is operating normally in CR
direction.
p. 440
8
Colorimetry PF
Inspection
Check if the Color Measurement
Device is operating normally in PF
direction.
p. 441
9
Take-up Reel USB
host check
Check if Auto Take-up Reel Unit
and Mounter are correctly
connected.
p. 442
C A U T I O N
The OS supporting the inspection program are Windows 2000
and Windows XP only.
If the red screen (NG screen) appears while inspecting, press
[Alt] + [E] keys on the computer’s keyboard to return to the
menu screen.
Confirm that STATUS is READY on the start screen for each
inspection. If it does not become READY, an error is occurring
in the printer or the connection is faulty.
Save the Service Program on the desktop or directly under the
C drive. If the storage location is deep in the hierarchy, some
program tools may not work correctly.