Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908 Revision I
ADJUSTMENT Tests 432
Confidential
5. Install the mounter on the printer.
6. Click on the [OK] button.
Figure 5-92. Mount Sensor Check Screen
7. Confirm the blue screen appears, click on the [OK] button.
Figure 5-93. Confirmation Screen
8. Enter the temperature around the printer and click on the [OK] button.
Figure 5-94. Temperature Input Screen
9. Take a measure according to the color of displayed screen.
Figure 5-95. Confirmation Screen
Screen
color
Description Remedy
Blue
No abnormality
Thermistor is operating normally.
Click on the [OK] button
Orange Detected temperature differs slightly
from entered temperature. Or the
correct value cannot be obtained from
the Thermistor.
Re-enter the temperature. If not
improved, replace the Thermistor.
(p. 337)
Yellow
Red
Detected temperature differs
considerably from entered
temperature. The thermistor might be
broken.
Replace the Thermistor. (p. 337)