EasyManuals Logo
Home>Epson>Robotics>T-B Series

Epson T-B Series Maintenance Manual

Epson T-B Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
T3-B T6-B Maintenance 4. Alarm
20 T-B series Maintenance Manual Rev.1
4.2.3 Alarm Notifying Method
The Manipulator status becomes warning and displays warning message if any parts
required to perform replacement or grease up.
For details, refer to the following manual.
Status Code / Error Code List
The alarm notifying method can be configured by the output bit of the Remote I/O.
The Remote I/O can be configured in the EPSON RC+ 7.0- [Setup] - [System Configuration]
- [Controller] - [Remote Control].
For details, refer to EPSON RC+ 7.0 User’s Guide 12.1 Remote I/O.
The controller enters the warning state if an alarm occurs.
Alarm1 to Alarm9 set in the output bit of the remote I/O monitor the occurrence of warnings
every 5 minutes.
The alarm occurrence and output timing on the controller are different. It may be output to
the remote I/O up to 5 minutes after the alarm is occurred on the controller.
4.2.4 How to Cancel the Alarm
An alarm occurs when the consumption rate of the parts reaches 100%.
The alarm cannot be canceled by executing the Reset command or restarting the controller.
The alarm can be canceled by the following method.
Operation from [Maintenance] dialog box of the EPSON RC+ 7.0
HealthCtrlReset Command
HealthRBReset Command
Refer to “4.2.2 How to Edit the Maintenance Information” to change the alarm
information in the same steps.
NOTE
NOTE

Table of Contents

Other manuals for Epson T-B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson T-B Series and is the answer not in the manual?

Epson T-B Series Specifications

General IconGeneral
BrandEpson
ModelT-B Series
CategoryRobotics
LanguageEnglish

Related product manuals