Table 3.21 Transport Stream Parameters
Parameter Description
Service List Select to manage services in the Transport Stream. (Next step.)
Current State Read Only displays current output state (online, offline)
Change State Online, Offline. Controls the actual presence of the Transport Stream in the output.
Transport Stream Bit rate 0.04 200 Mbps.
Reserved Bit rate
The amount of bit rate in the Transport Stream that cannot be allocated to any of the transmitted
components.
Bit rate Tracking Mode Off, Maximize Video.
Auto Enable
false, true. Specifies whether or not to automatically re-enable the Transport Stream (set its Setmode
state to Online) when the condition set in the Auto Disable field is not met.
Auto Disable
Never, Audio Lost, Video Lost, Audio or Video lost, Any UPSTREAM critical alarm, Any critical alarm.
Specifies the condition on which the Transport Stream has to be disabled. Audio lost and video lost
means that the audio or video lock of any of the components in the Transport Stream is lost,
UPSTREAM critical alarm is an alarm that is triggered by any of the components that contribute to
producing the elementary streams carried by the Transport Stream.
Syntax DVB, ATSC
Program Specific Information Transport Stream ID A new ID can be assigned to the Transport Stream.
PAT-PMT On, Off
PAT-PMT Parameters PMT Repetition Period
100 ms, 400 ms, 500 ms. Specifies how
often (in ms) the PMT shall be transmitted.
Dolby Digital Descriptor DVB, ATSC, DVB & ATSC
CAT On, Off
TSDT On, Off
TDT On, Off
EIT On, Off
Service Information
Original Network ID
NIT On, Off
NIT Parameters Network Name Set Network Name
Network ID Set network ID.
Generate LCN Off, IEC 62216, NorDig v1, DTG Default
Send extended NIT
(SIRG)
On, Off. If PSI/SI Level is set to On (PAT/PMT/SDT/CAT/NIT) make
sure the Send extended NIT (SIRG) is On so that the Carrier ID is
sent.
Insert NIT into PAT True, False
SDT On, Off
5. For an IP Transport Stream set up the IP related parameters as shown in