E.7 Alarms List – G.703 Transceiver Card
The following table lists the alarm and failure identifiers generated by the G.703
Transceiver card.
Table E.8 Alarm List – ASI I/O Option Card
Alarm Description Port Number Alarm ID Source Severity
Over Temperature Warning
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive.
0 01120001 G.703 I/O minor
Over Temperature
Failure to take action may cause
permanent damage to the unit.
Please switch it off and refer to
Customer Support.
0 01120002 G.703 I/O critical
Invalid Parameter
Invalid parameter received by the
Transceiver Card. Please see G.703
I/O Status for a more detailed
description of the error.
0 01120003 G.703 I/O critical
Option Card Build Version
Mismatch
The software on this option card is
not an officially released version.
0 01120008 G.703 I/O minor
CLAD Loss Of Lock failure
SCT Clock Rate Adapter PLL not
locked to internal clock reference
(hardware error). Please refer to
Customer Support.
1 01120010 G.703 I/O critical
Loss Of Signal (LOS) failure
No input or input signal level is too
low (>24dB below nominal). Please
check the G.703 Input port. Cable
might be faulty or too long.
1 01120020 G.703 I/O major
Alarm Indication Signal (AIS)
failure
Malfunction of far-end G.703
terminal. Please see FEAC
indication (if available) under G.703
I/O Status for details.
1 01120021 G.703 I/O major
Loss of Frame (LOF) failure
DS3 frame synchronization loss.
Framing might have been disabled
in the transmission.
1 01120022 G.703 I/O major
Remote Alarm Indication (RAI)
failure
Defects (LOS, LOF or AIS) detected
at far-end G.703 terminal input.
Please see FEAC indication (if
available) under G.703 I/O Status for
details.
1 01120023 G.703 I/O warning
Loss of Cell Delineation (LCD)
failure
Indefinite ATM cell boundaries. ATM
encapsulation might have been
disabled in the transmission.
1 01120024 G.703 I/O major
Corrupt Payload failure
ATM FEC schemes error correction
capability exceeded. Too many ATM
cell losses and/or too long errored
blocks in the transmission.
1 01120025 G.703 I/O major
Corrupt Payload failure
DVB FEC scheme's error correction
capability exceeded. Too long
errored blocks in the transmission.
1 01120026 G.703 I/O major