EasyManua.ls Logo

Ericsson AVP 1000 - Configure Option Card Output Parameters; How to Configure Output Transport Streams

Ericsson AVP 1000
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Getting Started
3-16
EN/LZT 790 0023/1 R16A
3.8.2.2 Configure Option Card Output Parameters
Note: An output MUST have a Transport Stream created and set to Online
before the output signal will be present.
To configure the Option Card Output Parameters:
1. Configure the parameters for satellite transmission by navigating to Encoder >
Slots > Slot n Satellite Modulator Option Card > Satellite Modulator
Option Card. The input, modulation and output parameters can be set up by
selecting the Input Parameters, Modulation Parameters and Output Parameters
folder and entering the required information, as shown on the picture below. To
enable the output ensure that a Transport Stream has been created (this can be
an empty Transport Stream if just a signal test is required). Set the Transport
Stream status to Online. Set the Output State to either On (Reduced Power)
or On (Nominal Power), and when required set Modulation State to On.
Figure 3.4 Setting the Parameters for Satellite Transmission
2. The ASI outputs can be configured to be mirrored (same TS on both outputs) or
independent. There are no other configurable parameters for the ASI outputs
3. The format of the G703 Output is configured by navigating to Encoder > Slots >
Slot n G>703 Transceiver Card > G.703 Transceiver Card > G.703 I/O Port
1.
3.8.3 How to Configure Output Transport Streams
To configure a Transport Stream for an AVP, follow the steps below. Here, the
Satellite Modulator output is taken as example. Transport Streams also can be
easily configured on other outputs using the same procedure.