Installing the Equipment
2-6
EN/LZT 790 0023/1 R16A
2.3.3 Control Ethernet Connector
The Ethernet control ports are used to connect the
equipment to a PC for access with a web browser. Both
connectors share the same IP address, CTL 1 is the
Primary control port, and is by default the active control
port. Control Port CTL 2 should be considered as the
secondary control network as it will not respond to the
Control Port IP Address unless control has been passed
to it either as a result of a redundancy switch, or via a
user command. The active control port switches when
CTL 1 has no link (e.g. carrier), and CTL 2 has the link.
Table 2.4 Control Ethernet Connector
Item Specification
Connector type RJ-45 (100/1000 Base T)
Connector designation CTL 1
CTL 2
Pin outs
(Unused pins are not
connected)
Pin 1 - Tx Out (+)
Pin 2 - Tx Out (-)
Pin 3 - Rx In (+)
Pin 6 - Rx In (-)
Status and Activity Indication
Each Ethernet Control Port has rear panel mounted status LEDs to indicate link
status, activity and speed as follows:
Table 2.5 Port Status: Left (Green) LED
Port
Status
Link Speed LED Status
Active
Port
No Link Off
— — — — — — — — — — — — — — — — — —
100 Mbps Flash Off x 2
1000 Mbps Flash Off x 3
Spare
Port
No Link Off
— — — — — — — — — — — — — — — — — —
100 Mbps Flash On x 2
— — — — — — — — — — —
1000 Mbps Flash On x 3
— — — — — — —
The left LED flash sequence period is 1 s, with a short flash duration of 100 ms.